Symphony® Thrombectomy System

Take the guesswork out of VTE.

Symphony is the only 24F and 16F pump-based thrombectomy system designed to take the guesswork out of venous thromboembolism (VTE) procedures by providing real-time feedback that enables physicians to make more purposeful, confident decisions.

VTE thrombectomy can
lack predictability

The challenge in VTE procedures today is the lack of real-time information to guide physicians’ next steps, which can lead to repeated device introductions and exchanges and, most importantly, wasted time during an emergent procedure.

Real-time feedback with Symphony

The Symphony Thrombectomy System, labelled: 16F/24F sizes to telescope and reach distal anatomy; on-demand pulses of vacuum; clot capture confirmation, in-line pressure monitoring & fluid injection; directional control rotational collar; anti-clogging ProHelix® Mechanical Assist
The Symphony Thrombectomy System
  • 16F/24F sizes to telescope and reach distal anatomy
  • Directional control rotational collar
  • On-demand pulses of vacuum
  • Clot capture confirmation, in-line pressure monitoring & fluid injection
The ProHelix mechanical assist tip

Anti-clogging ProHelix® Mechanical Assist

Simplified procedure

Symphony’s multiport provides a direct line to the tip of the catheter, giving physicians immediate insight into clot and catheter position throughout the procedure. Confirm clot capture while distal in the anatomy, helping avoid the reintroduction of accessories that can add time and complexity to procedures.

The Symphony catheter handle, with an arrow to its multiport line beside the vacuum line

One catheter from start-to-finish

Symphony is the only thrombectomy system that allows physicians to customize aspiration to match the patient’s needs. By adjusting the vacuum, physicians can maintain a 24F catheter throughout the entire case, targeting stubborn clot in challenging anatomies without limitations of small catheters.

The Symphony pump

Maintain position

The ProHelix® Mechanical Assist device works over the wire and uses an Archimedes screw design to ingest corked clot without losing position or re-crossing the heart for faster, more efficient cases.

The Symphony 24F catheter with the ProHelix mechanical assist engaging clot

SYMPHONY-PE Trial

Objective

To evaluate the safety and efficacy of the Symphony Thrombectomy System in the treatment of patients with acute intermediate-risk pulmonary embolism.

High efficacy

  • 38.4 %

    Clot burden reduction based on Refined Modified Miller Index

    Largest reduction compared to IDE trials*

  • 7 mmHg

    Reduction in mean pulmonary artery pressure (PAP)

    Largest reduction compared to IDE trials*

  • 0.44 RV/LV

    Mean reduction in right ventricle–to–left ventricle ratio

    Exceeded the prespecified performance goal of > 0.20

Fast procedure

  • 31 min

    Median device-use time

    Fastest reported median time*

  • 16F/24F continuous deep vacuum

    Rapid clot evacuation without increased blood loss

  • Streamlined procedure

    Intraprocedural pulmonary artery pressure (PAP) assessment and contrast imaging

Excellent safety

  • 0.9 %

    Major adverse event (MAE) through 48 hours

    0.0% device-related serious adverse events (SAE)

  • 0 %

    All-cause mortality rate

    Measured through 30 days

  • 250 mL

    Median aspirated blood

    Minimal aspirated blood and no periprocedural blood transfusions

*A Prospective Multicenter IDE Study of the Next-Generation Precision Aspiration Thrombectomy System for Intermediate-Risk Pulmonary Embolism: The SYMPHONY-PE Trial
*No head-to-head clinical trials have been conducted.